scopex csa 660 benchtop rohs analyzer-凯发k8娱乐登凯发k8娱乐登录

400-992-0512  

scopex csa
> products >
scopex csa 660 benchtop rohs analyzer

product introduction
designed for rapid rohs/elv compliance and halogen-free analysis, the lanscientific scopex csa high-level analyzer utilizes superior testing technology, innovative x-ray optics design and an intelligent software system to quickly and reliably determine whether a sample contains hazardous substances. it has the advantages of simple sample preparation, high analysis accuracy, wide range of analyzable elements, simple and rapid testing, etc., and the results are reliable and accurate, in line with the new national standard.

how scopex works
wave sound scopex energy dispersive x-ray fluorescence spectrometer uses the principle of x-ray fluorescence analysis.

the principle of x-ray fluorescence analysis
by irradiating the sample with x ray of a certain wavelength, the element is in the excited state and produces excited photons, forming a kind of fluorescence x ray. the energy of the excited states of different elements is different, and the fluorescence x rays produced are different. qualitative analysis is carried out by detecting the wavelength of x-rays, and quantitative analysis is carried out by detecting the specific x-rays of the elements.

operating principle of instrument
the instrument's high-voltage power supply provides tube pressure and tube flow to the optical tube. the optical tube excites continuous x-rays, which are radiated to the sample to produce x-ray fluorescence with sample characteristics. after entering the detector, the signal becomes voltage signal, which is amplified and processed by the computer after data acquisition.




technical parameters and specifications

the main specifications


the measurement

x-ray fluorescence analysis

determination method

energy dispersion type

the determination of the object

solid, liquid, powder

range of measurement

sodium (na) -uranium (u)

sample room size

368*304*78mm

maximum sample weight

2.5 kg

open way

the automatic control

x - ray generating department


x-ray tube

high power side window x-ray tube

voltage

maximum 50 kv

current

limit 1 ma

cooling way

air cooling

collimator

5mm, 3mm, 1mm, 0.5mm

the detector


type

sdd detector

cooling way

peltier cooling

sample room


determination of environmental

atmosphere, vacuum (optional), helium (optional)

sample observation

5 megapixel high-definition industrial camera

data processing department


pc processor (cpu)

i3-7100 equivalent frequency or above

memory (ram)

ddr4 4g memory or above

hard disk capacity (rom)

1tb hdd or 256gb ssd or above

os

windows 10

environment setup


temperature conditions

10 ° c ~ 35 ° c

relative humidity

40~70%(no dew)

the power supply

220vac

rated power

100w

set the example


size of the host

570*402*400mm

the host weight

47kg

principal configuration:

1. efficient side window x-ray tube (ag/rh target).

2. high-voltage power supply.

3. configuration of large-area sdd detector.

4. large sample measurement chamber.

5. high-definition cameras.

6. automatic switching collimator and filter.

7. computers and laser printers.

8. spectral analysis software suite

9. reference material: system calibration calibration sample

10. other equipment: sample cup, test film, fuse.


product detail

the hardware configuration


high sensitivity


the combination of high-power and high-efficiency x-ray tube and high-performance si-pin detector brings a very low detection limit and can detect trace harmful substances quickly and accurately.with only one instrument, sample compliance monitoring can be performed with high efficiency and high quality.


accurate and reliable


xrf analysis software with wave sound, combined with empirical coefficient method, basic parameter method (fp method) and other analysis methods, the accuracy of test data performance is guaranteed.

empirical coefficient method: the instrument determines the influence coefficient according to the determination of the standard sample.the standard sample is required to be of similar type to the sample to be tested, and the calibration model is simple.

basic parameter method (fp method) : the instrument according to the actual detection of substances, through a variety of physical quantity modeling calculation to determine the parameters.the standard sample requirements are not high, the calculation is more complex, suitable for the lack of the corresponding standard sample material detection.


screening of hazardous substances


scopex provides analytical screening for hazardous metal elements that are limited by environmental regulations such as rohs/elv, and further standard halogen detection capabilities. halogen-free analysis can also be easily perfor


relevant standards

the relevant standard

response to the instructions

response to eu rohs2.0 directive -- 2011/65/eu

react to halogen-free directive iec61249-2-21

response to reach directive

react to toy en71 instruction

addressing the cpsia consumer product safety improvement act

voluntary certification should be introduced by china-rohs

conform to iec62321 standard

in accordance with gb/t26125-2011


related video
related products
  • scopex csa 600 benchtop rohs analyzer
    lanscientific scopex is an x-ray fluorescence analyze...

  • scopex csa 600f benchtop rohs analyzer
    halogens or halogens include five chemical elements: ...

lanscientific co., ltd.
suzhou lanscientific co.,ltd.is a professional manufacture, production and sale of portable x fluorescence analysis instrument of the provincial high-tech enterprises. the company has the domestic first-class team of experts x fluorescence analysis technology, with strong technical strength, advanced technology, service concept and advanced management mode...
凯发k8娱乐官网网址多少 copyright © 2016 suzhou lanscientific co.,ltd.  support:   
friendship link: